📅 --/--/----
USD USD: TRY
EUR EUR: TRY
GBP GBP: TRY
Envanter 0,00
0
0
Subtotal: 0,00

No products in the cart.

No products in the cart.

Phoenix Contact MACX MCR-T-UI-UP-SP

Phoenix Contact
    Add a header to begin generating the table of contents

    MACX MCR-T-UI-UP-SP – Temperature Measurement Transducer

    In industrial processes, precise measurement depends on robust temperature measurement transducer solutions. The Phoenix Contact MACX MCR-T-UI-UP-SP delivers reliable performance across diverse applications thanks to its compatibility with RTD and thermocouple sensors. Its 4–20 mA analog output preserves signal integrity while enabling straightforward integration into process automation systems.

    Designed for production line safety and operational continuity, the MACX MCR-T-UI-UP-SP temperature transducer guarantees a high safety level with its SIL2 certification. Push-in connection technology streamlines installation and maintenance, while the compact DIN-rail form factor saves valuable panel space. As a result, plants gain both reliability and efficiency in their process automation infrastructure.

    Temperature Measurement Transducer – Application Areas

    Temperature measurement transducers play a critical role across a wide range of industries—from energy plants and chemical facilities to food production lines and the pharmaceutical industry. Working with RTD and thermocouple sensors, these devices ensure dependable measurements for process control, heating and cooling systems, furnace and boiler automation, petrochemical production, and laboratory applications. Their high accuracy and SIL2-certified safety make them indispensable in both industrial automation systems and safety-critical applications.

    Phoenix Contact MACX MCR-T-UI-UP-SP Wiring Diagram

    The Phoenix Contact MACX MCR-T-UI-UP-SP temperature measurement transducer offers straightforward cabling thanks to its compact DIN-rail design. In the wiring diagram, you can clearly identify the RTD or thermocouple inputs, the 4–20 mA analog output, the limit relay contacts, and the wide supply voltage terminals. With both Push-in and screw connection options, cable installation is fast and the risk of miswiring is minimized—ensuring safe, correct commissioning of the transducer in the automation panel.

    MACX MCR-T-UI-UP-SP Wiring Diagram
    Connection Point Function Description
    RTD / Thermocouple Input Sensor Connection 2-, 3-, or 4-wire RTD sensors and various thermocouple types
    Analog Output Signal Transmission Integration to PLC/DCS systems via 4–20 mA or voltage output
    Limit Relay Contact Alarm Output Relay output for adjustable setpoint; suitable for alarm and safety applications
    Power Supply Input Power Wide-range power supply (24–230 V AC/DC) for device operation
    Grounding / Isolation Safety Protective earth connection and 4-way isolation for safe operation

    MACX MCR-T-UI-UP-SP Connection Features

    The Phoenix Contact MACX MCR-T-UI-UP-SP temperature transducer enables secure integration with PLC/DCS systems via RTD and thermocouple inputs, a 4–20 mA analog output, an adjustable limit relay contact, a wide-range power supply, and SIL2 isolation. Push-in and screw terminals support fast commissioning and low maintenance, while the compact DIN-rail design saves panel space and ensures stable measurement in demanding process automation applications.

    MACX MCR-T-UI-UP-SP Advantages

    In demanding industrial environments, the MACX MCR-T-UI-UP-SP delivers high accuracy within a compact DIN-rail footprint that fits even tight panels. Its SIL2 certification supports safety-critical processes, while 4-way isolation reduces measurement errors and electrical noise. Together, these attributes increase production efficiency and provide long-term safety with a lower total cost of ownership.

    Benefits For Engineers

    The Phoenix Contact MACX MCR-T-UI-UP-SP consolidates field needs into a single temperature transducer. Compatible with RTD and thermocouple sensors, it delivers a stable 4–20 mA signal to PLC/DCS platforms. Its SIL2 safety level and 4-way isolation cut measurement errors and electrical noise in demanding environments, while DIN-rail mounting, push-in terminals, and a wide-range power supply enable fast commissioning with low ongoing maintenance.

    Conclusion & Buying Guide

    The Phoenix Contact MACX MCR-T-UI-UP-SP brings your field temperature measurement transducer needs into a single device with RTD/thermocouple compatibility, a 4–20 mA analog output, and SIL2 safety. It delivers stable measurements on industrial lines with fast commissioning and low maintenance, ensuring smooth PLC/DCS integration in process automation.

    1 thought on “Phoenix Contact MACX MCR-T-UI-UP-SP”

    Leave a Comment

    Your email address will not be published. Required fields are marked *

    WhatsApp Mail
    0
      0
      Your Cart
      Your cart is emptyReturn to Shop