Titreşim Ölçme Sistemleri & Anahtarlar.

Vibration Switch

Safe Vibration Switch shutdown systems with relay output, adjustable delay.

Monitoring Systems

Acceleration, velocity, and temperature alarms with reporting on one platform.

PLC/SCADA Entegrasyon

Easy connection with 4-20 mA and relay signals, fast commissioning.

ATEX & ISO 10816/20816

Hazardous area options and standards-based alarm management.

Vibrations Switchs 4-20mA Transmitters

For critical assets, Hansford’s vibration switch and monitoring systems secure production continuity. The vibration switch provides a relay output when the threshold is exceeded, with adjustable setpoint and delay; it can operate on mm/s RMS or g levels. With PLC/SCADA compatibility and optional 4–20 mA feedback, it integrates quickly on site, and ATEX options enable safe use in hazardous areas.

The monitoring systems collect acceleration, velocity and temperature across multiple channels, delivering trend analysis, alarm management and reporting. Automatic thresholding to ISO 10816/20816 limits strengthens predictive maintenance strategies and reduces unplanned downtime. Data archiving, on-site readout via a display unit and central PLC/SCADA integration provide a transparent, scalable vibration monitoring platform.

Vibration Monitoring

Modules that condition IEPE accelerometer signals connect directly to PLC/SCADA via 4–20 mA analog and relay outputs. Adjustable threshold, hysteresis and delay settings reduce false trips in vibration switch mode; status LEDs and quick-connect terminals speed commissioning.

A multi-channel vibration monitoring architecture continuously measures and logs mm/s RMS or g levels, applying warning and stop logic to ISO 10816/20816 machine classes. With ATEX-compliant sensor combinations, operation in hazardous areas is safe; a robust data set supports predictive maintenance and production continuity.

Vibration Switch Applications

Electronic vibration switches and multi-channel monitoring systems deliver vibration monitoring and instant protection across a wide range of assets: from cooling towers and HVAC chillers in power plants; to cement grinding mills, crusher–screen stations and conveyors; to water & wastewater lift stations and chemical/petrochemical dosing/circulation skids; and to paper & pulp calenders, plus mixers and filling lines in food & beverage. With PLC/SCADA integration and ATEX-compliant options, they provide early warning to prevent bearing and misalignment-related failures before they escalate, improving uptime and process continuity.

Vibration Monitoring, Equipment Protection & Signal Conditioning

The Hansford Vibration Systems & Switches brings together Monitoring Systems, Vibration Switches, Charge Amplifiers, Accelerometer Power Supply Modules, Display Units and Module Enclosures in a single ecosystem. Inputs from IEPE sensors (acceleration/velocity) are precisely conditioned and connected to PLC/SCADA via 4–20 mA and relay outputs, streamlining trending, alarms and reporting. Compact DIN-rail designs and rugged housings enable reliable field installation, while ATEX and ISO 10816/20816 compliance standardize vibration monitoring and protection on critical machinery.

Ne zaman monitoring system, ne zaman vibration switch?

Basit koruma için vibration switch yeterlidir. Çok kanallı monitoring system trend, teşhis ve raporlama gerektiğinde tercih edilir.

Evet; IEPE accelerometer sabit akım besleme ister. IEPE girişli cihaz yoksa accelerometer power supply module kullanılır.

Makine sınıfını belirleyip mm/s RMS sınırlarını seçin; PLC’de 4–20 mA ölçekleme ile Uyarı/Trip eşikleri tanımlayın.

Charge amplifier ne zaman gerekir?

Charge accelerometer pC/üretir; bu sinyalin gerilime dönmesi için charge amplifier gerekir. Uzun kablo ve yüksek sıcaklıkta da avantaj sağlar.

ATEX sertifikalı sensör/modüller ve uygun bariyer/izolatör ile kullanılabilir. Kurulumda topraklama ve “entity parameters” şartlarına uyun.

Gerekli IP sınıfı, pencere/tuşla reset ve DIN-ray uyumu önemli. Saha okumaya ihtiyaç yoksa yalnızca PLC/SCADA üzerinden izleme yeterlidir.

G.M. International SIL2/3 ATEX IECEx Solutions

WhatsApp Mail