SIL certified relays are used in Oil & Gas or petrochemical industries.
Safety Relays
Emergency Stop Relays
SIL 2/3 Certified
Functional safety assurance
Data from Field To Cloud
Real-time data transfer
HART® & Digital
Smart device integration ease
GMI SIL Certified Safety Relais Series
G.M. International Safety Relays implement process safety functions with proven reliability. With mechanically linked (positively guided) contacts, dual-channel inputs, manual/automatic reset, feedback and status LEDs, they ensure consistent actuation in Emergency Stop, valve shutdown, and machine/plant stop scenarios. The compact DIN-rail housing simplifies panel layout and speeds commissioning and maintenance.
Thanks to native compatibility with DCS/PLC infrastructures, it establishes a safe switching layer in ESD, F&G, BMS, and HIPPS architectures, supports 1oo1, 1oo2, and 2oo3 voting schemes, and simplifies periodic proof-test routines. A design aligned with IEC 61508/61511 and a manufacturing discipline certified to ISO 9001:2015 ensure traceability and documentation integrity across process safety projects.
- Smart device integration ease
- ATEX & IECEx Certified
- Intrinsically Safe Isolators
- Multiplexer Systems
- 4–20 mA Analog Isolation
- HART® & Digital Integration
GMI D5095S Safety Relay
D5095S is a SIL 3 safety relay designed for switching safety-related circuits. It provides input–output isolation, and its 2+2 NC contacts (parallel then series) lower spurious trip risk while delivering high process availability for NE/ND and F&G loads; DCS/PLC pulse-test compatibility streamlines commissioning and periodic proof testing.
Installs compactly on DIN-rail; with optional both-pole load disconnection and a 5 A relay output, it serves as a reliable interposing relay in ESD/F&G layers. Supports SIL documentation and safety-manual calculations in accordance with IEC 61508.
Safety Relay Applications
Safety relays are used in process plants for Emergency Stop circuits, valve shutdown and interlock logic, burner/furnace safety, compressor/pump protection, conveyor and crane stop scenarios, as well as gas detection (F&G) and ESD trips. In SIL 2 / SIL 3 targeted applications, they create a safe interposing layer with DCS/PLC, supporting open-/short-circuit monitoring, feedback verification, and periodic proof-test routines. The compact DIN-rail format simplifies cabinet layout and speeds maintenance and commissioning, enabling safe and traceable operation across Oil & Gas, petrochemical, power, water/wastewater, and steel industries.
Hazardous Area Management & Integration: Safety Relays
Beyond selecting the right safety relay, a clear commissioning, maintenance, and retrofit strategy is critical. In SIL2 and SIL3 targeted architectures, relays integrate seamlessly with safety PLCs and DCS/SCADA. Features such as force-guided contacts, feedback monitoring, and test/reset functions accelerate fault detection, support scheduled proof tests, and reduce downtime. IECEx and ATEX compliant models align with field wiring, terminal standards, and labeling practices, simplifying maintenance. The G.M. International portfolio, with common footprints, accessory compatibility, and coherent spares policies, minimizes cabinet changes in retrofit projects and enhances safety function traceability.
Which Protocols Are Supported?
It provides full compatibility with analog and digital signals such as 4–20 mA, 1–5 V, HART®, Modbus, and Profibus.
How to Install & Assemble a Safe Isolator?
Thanks to its modular design, it offers quick DIN rail mounting and easy integration with screw connectors.
Maintenance Interval - Technical Support?
Annual visual inspection and functional testing are sufficient; operational safety is ensured with 24/7 technical support.
What Are Self-Confident Insulators?
All our models are designed to fully meet ATEX, IECEx, and SIL 2/3 requirements.
What Certifications Does It Have?
Functional safety SIL 2 / SIL 3 in accordance with IEC 61508, supporting IEC 61511 use cases.
What Are the Model Selection Criteria?
The appropriate isolator is selected based on your application’s signal type, operating temperature, and functional safety level (SIL) requirements.
G.M. International SIL2/3 ATEX IECEx Solutions
-
Analog Input
D5015SS SIL2 HART® Transmitter Power Supply
₺9.400,00Original price was: ₺9.400,00.₺8.299,00Current price is: ₺8.299,00. -
Analog Input
D5015SK SIL2 HART® Transmitter Power Supply
₺8.799,00Original price was: ₺8.799,00.₺8.199,00Current price is: ₺8.199,00. -
Analog Input
D5014S SIL3 2/4-Wire HART® Transmitter Power Supply
₺9.679,00Original price was: ₺9.679,00.₺9.449,00Current price is: ₺9.449,00. -
Analog Input
D5014D SIL3 2/4-Wire HART® Transmitter Power Supply
₺22.199,00Original price was: ₺22.199,00.₺17.233,00Current price is: ₺17.233,00. -
Analog Input
D5011S SIL3 2-Wire HART Transmitter Power Supply
₺9.309,00Original price was: ₺9.309,00.₺8.799,00Current price is: ₺8.799,00. -
Analog Input
D5011D SIL3 2-Wire HART Transmitter Power Supply
₺13.698,00Original price was: ₺13.698,00.₺12.499,00Current price is: ₺12.499,00.